PureCell® Model 400 Energy Solution

Introducing a new generation of fuel cell technology: The PureCell® Model 400 Energy Solution.

UTC Power is a world leader in developing and producing fuel cells for on-site power, transportation, space and defense applications. We are committed to providing high quality solutions for the distributed energy market that increase energy productivity, energy reliability and operational savings for our customers. Building on our unmatched operational experience and a technology platform proven at more than 260 sites worldwide, UTC Power is pleased to offer an advanced fuel cell energy solution for the commercial marketplace.

The ultra clean and quiet PureCell® Model 400 fuel cell can provide up to 400 kW of assured electrical power, plus up to 1.7 million Btu/hour of heat, for combined heat and power applications. And with energy efficiencies more than double those of traditional power sources, the PureCell® Model 400 system is an energy solution that will not only help you conserve precious resources, it will save you money, shield you from operational interruption, and secure your place at the forefront of environmentally sustainable business practices.

Performance Characteristics

Power

Efficiency

Electric power


Voltage/frequency
400 kW/400 to 471 kVA initial
400 kW lifetime average
360 kW initial (ADG)
480VAC/60 Hz/3 phase**
400VAC/50 or 60 Hz/3 phase
NOx
CO
CO2
SOx
Particulate matter/VOCs
0.035 lb/MWh (0.016 kg/MWh)
0.008 lb/MWh (0.004 kg/MWh)
1120 lb/MWh (508 kg/MWh) average
Negligible
Negligible
Efficiency Water
Electrical (LHV)
Overall (LHV)
42% initial/40% nominal (5 yr)
90%***
Consumption
Discharge
None (up to 86°F/30°C ambient)
None (normal operating conditions)
Fuel Heat Recovery

Supply
Consumption (HHV)



Pressure

Natural gas or ADG†
3.60 MMBtu/hr (1,054 kW) initial
3.79 MMBtu/hr (1,110 kW) average
3,493 scfh (98.9 Nm3/hr) initial
3,678 scfh (104.2 Nm3/hr) average
4 to 14 in. water (1.0 to 3.5 kPA)‡
Low grade
(60°C/140°F supply)§


High grade
(121°C/250°F supply)§

1.537 MMBtu/hr (450 kW) initial
1.708 MMBtu/hr (500 kW) nominal


0.683 MMBtu/hr (200 kW) initial
0.785 MMBtu/hr (230 kW) nominal

Power Module Shipping Dimensions Cooling Module Shipping Dimensions
Length:
Width:
Height:
Weight:
27 ft, 6 in. (339 cm)
8 ft, 6 in. (111 cm)
10 ft (305 cm)
60,000 lb (27,216 kg)

Length:
Width:
Height:
Weight:

15 ft, 11 in. (485 cm)
7 ft, 10 in. (239 cm)
6 ft, 7 in. (201 cm)
3,190 lb (1,447 kg)
Other

Noise

Overhaul interval

<65 dBA at 33 ft (10m) with no heat recovery
<60 dBA at 33 ft (10m) with full heat recovery
10 yr

* Emissions meet 2007 California Air Resources Board standards.
** Operating range from -20° to 113°F (-29° to 45°C) at up to 429 ft (150m).
*** Overall efficiency as given assumes full thermal utilization.
† All given characteristics are for a natural gas application, unless otherwise noted. Maximum allowable levels for natural gas components are documented separately in the PureCell® Model 400 System Installation Design Guide. ADG applications require an additional gas processing unit.
‡ Gauge pressure.
§ Available heat at rated power. Low-grade heat assumes a return temperature of 80°F (27°C); high-grade heat assumes a return temperature of 194°F (90°C). If high-grade heat is utilized, the remaining value will be available as low-grade heat.


Associated File(s)Associated File(s)

Download Acrobat Reader Datasheet




Add to Basket
Add to Basket

Quotation Only - Add this item to the basket to request
Contact Us
Contact Us

Request more information on this product
Return to portal
  Previous Page
Copyright © 2002-2008 UTC Power
Terms & Conditions
 Back to Top   
Expand Menu
Expand Menu
Expand Menu
M
y

B
u
s
i
n
e
s
s

C
a
r
d