Capacity c10: 110 - 200 & 18-110 Ah
Cycle life to 80% depth of discharge (IEC 896): 1000
Design life: 15 Years
Discharge time: 10 mins to 100hr
Operarting voltage: 12 Volt Monobloc
Product chemistry: Lead Acid
|
|
|
|
Capacity c10: 100 to 3200 Ah
Cycle life to 80% depth of discharge (IEC 896): 2000
Design life: 20 Years
Discharge time: 5 mins to 24hrs
Operarting voltage: 2 Volt cells
Product chemistry: Lead Acid
|
|
|
|
Capacity c10: 40 to 175 Ah
Cycle life to 80% depth of discharge (IEC 896): 800 - 1200
Design life: 10 to 12 Years
Discharge time: 5 mins to 24hrs
Operarting voltage: 12 Monobloc
Product chemistry: Lead Acid
|
|
|
|
Capacity c10: 100 to 3000 Ah
Cycle life to 80% depth of discharge (IEC 896): 2000
Design life: 15 Years
Discharge time: 10mins to 100hr
Operarting voltage: 12 Monobloc
Product chemistry: Lead Acid
|
|
|
|
Capacity c10: 40 to 230 Ah
Cycle life to 80% depth of discharge (IEC 896): 1200
Design life: 12 Years
Discharge time: 5 mins to 24 hrs
Operarting voltage: 6 - 12 Monobloc
Product chemistry: Lead Acid
|
|
|
|
Capacity c10: 100 to 3200 Ah
Cycle life to 80% depth of discharge (IEC 896): 1000
Design life: 15 Years
Discharge time: 5 mins to 24 hrs
Operarting voltage: 2 Volt cells
Product chemistry: Lead Acid
|
|
|
|
Capacity c10: 15 to 241 Ah
Cycle life to 80% depth of discharge (IEC 896): 1200
Design life: 10 to 12 Years
Discharge time: 15 mins to 100 hrs
Operarting voltage: 6 - 12 Monobloc
Product chemistry: Lead Acid
|
|
|
|
Capacity c10: 200 to 3000 Ah
Cycle life to 80% depth of discharge (IEC 896): 2000
Design life: 15 Years
Discharge time: 10 mins to 120 hrs
Operarting voltage: 2 Volt cells
Product chemistry: Lead Acid
|
|
|
|
Capacity c10: 15 to 275 Ah
Cycle life to 80% depth of discharge (IEC 896): 800
Design life: 12 Years
Discharge time: 5 mins to 24 hrs
Operarting voltage: 6 - 12 Monobloc
Product chemistry: Lead Acid
|
|
|
|
Capacity c10: 100 to 150 Ah
Cycle life to 80% depth of discharge (IEC 896): 2000
Design life: 18 Years
Discharge time: 15 mins to 20hrs
Operarting voltage: 12 Monobloc
Product chemistry: Lead Acid
|
|
|
|
Capacity c10: 16 to 241 Ah
Cycle life to 80% depth of discharge (IEC 896): 1200
Design life: 10 to 12 Years
Discharge time: 15 mins to 100hrs
Operarting voltage: 6 - 12 Monobloc
Product chemistry: Lead Acid
|
|
|
|
Capacity c10: 100 to 3000 Ah
Cycle life to 80% depth of discharge (IEC 896): 2000
Design life: 20 Years
Discharge time: 30 mins to 100 hrs
Operarting voltage: 2 Volt cells
Product chemistry: Lead Acid
|
|
|
|
Capacity c10: 3 to 248 Ah
Cycle life to 80% depth of discharge (IEC 896): 1000
Design life: 10 Years
Discharge time: 5 mins to 100hrs
Operarting voltage: 6 - 12 Monobloc
Product chemistry: Lead Acid
|
|
|
|
Capacity c10: 1 to 148 Ah
Cycle life to 80% depth of discharge (IEC 896): 2500
Design life: 20 Years
Discharge time: 5 mins to 10hrs
Operarting voltage: 1.2 Volt cells
Product chemistry: Nickel Cadmium
|
|
|
|
Capacity c10: 1.2 to 250 Ah
Cycle life to 80% depth of discharge (IEC 896): 800
Design life: 10 Years
Discharge time: 5 mins to 24 hrs
Operarting voltage: 6 - 12 Monobloc
Product chemistry: Lead Acid
|
|
|
|
The revolutionary VRLA Catalyst changes the electrochemical actions within the cell, extends battery life and the operating temperature range of VRLA batteries, Catalysts have many other advantages
|
|
|
|