Direct FuelCell® DFC®300MA™ 300 kW 480VAC 333 kVA 50 or 60 Hz
The DFC300MA™ is a commercial grade power plant capable of providing high quality base load electric power using natural gas or anaerobic digester gas as a fuel. The powerplant consists of three subsystem sections. The DFC Module includes the assembly of electrochemical cells that produce the DC power. The Electrical Balance of Plant section converts the DC power into high quality AC power. The Mechanical Balance of Plant section contains the process equipment that prepares air, fuel, and water for use in fuel cell stack module. Each DFC300MA™ is covered under FCE’s standard warranty.
Direct FuelCell Advantages
- Sitability
- Ultra Low Emissions
- Low Noise
|
Ultra low emissions of NOX and SOX allow the DFC® products to be placed in areas where emissions restrictions prohibit traditional generation technologies. |
- Applicability
- Low Profile
- Modular Design
|
DFC® products have been designed for installation at a wide variety of sites including industrial, commercial and institutional areas. The modular design allows for multiple units to be combined, providing incremental capacities. |
Direct FuelCell Applications
End Users
- Low cost on-site power generation
- Solution for premium power needs
- Environmental compliance
- Utilities
- Transmission & distribution grid support
- Grid congestion relief
- Environmental compliance
- Cogeneration/Combined Heat & Power (CHP)
- Steam, High Temperature Hot Water and Absorption Cooling
- District Heating and Cooling
- Alternative Fuels
- Wastewater treatment / anaerobic digester gas (ADG)
Experience & Capabilities
With more than 35 years of experience, FuelCell Energy is recognized as a world leader in the development, manufacture and commercialization of fuel cells for stationary electric power generation. The result of years of research and the investment of more than $530 million, our patented, carbonate Direct FuelCell technology has been demonstrated successfully in the field.
Strong Distribution and Services Alliances
Caterpillar; MTU CFC Solutions, GmbH; Marubeni Corp.; PPL Energy Plus; LOGANEnergy; Chevron Energy Solutions; Alliance Power; Renewable Technologies, Inc.; and Enbridge Inc.
Our patented Direct FuelCell® technology delivers reliable power efficiently, simply and economically. These qualities, combined with ultra-low emissions and quiet operation, provide all the elements necessary to make distributed power generation the best choice – right now – for large commercial and industrial facilities, institutions, municipalities and utilities.
| Dimensions and Weights |
Stack Module |
Height, feet |
8.4 |
Width, feet |
8.2 |
Length, feet |
15.0 |
Weight, lbs |
35,000 |
MBOP |
Height, feet |
Main Enclosure |
9.6 |
With ship-loose items installed |
14.6 |
Width, feet |
8.0 |
Length, feet |
19.8 |
Weight, lbs |
27,000 |
EBOP |
Height, feet |
9.5 |
Width, feet |
3.5 |
Length, feet |
9.0 |
Weight, lbs |
15,000 |
|
Power Output, ISO conditions |
Power at Plant Rating, kW |
300 |
Standard Output Voltage, Volts |
480 |
Standard Frequency, Hz |
60 |
Optional Output Voltages |
460, 440, 420, 400, 380 |
Optional Output Frequency |
50 |
|
Efficiency at Rated Output at ISO conditions |
LHV Efficiency, percent (see Note 1) |
47 +/-2%1 |
|
Fuel Consumption at Rated Output |
Natural gas (at 930 Btu/ft3), scfm |
39 |
Heat rate, Btu/kWh (LHV) |
7,260 |
|
Water Consumption at Rated Output |
Average, gallons per minute |
2.4 |
Peak during WTS backflush, gpm |
10 |
|
Water Discharge at Rated Output |
Average, gallons per minute |
1.2 |
Peak during WTS backflush, gpm |
10 |
|
Available Heat at Rated Power |
Exhaust Temperature, deg F |
650 |
Exhaust Flow, lb/h |
3,360 |
Allowable Backpressure, iwc |
5 |
|
Noise (see Note 2) |
72dB(A) at 10 feet 2 65 dB(A) option available |
|
Emissions |
NOx, lb/MWh |
0.02 |
SOx, lb/MWh |
0.001 |
CO, lb/MWh |
0.10 |
Note 1: Efficiency at acceptance shall be based on on-board instrumentation. Performance testing with additional high accuracy instrumentation is available for an additional fee. Power output and efficiency are subject to ISO correction according to FCE document #5841. Efficiency value is based upon natural gas fuel meeting FCE's fuel specification. Fuel composition or ambient condition changes after acceptance testing may affect performance as described in the FCE Fuel Specification document #5665.
Note 2: Noise specified is estimated noise level 10’ from plant perimeter in free field. Specific site conditions, such as proximity to other structures or equipment, will impact actual noise level at site.
|